MEWOI3000D-0.010Ω~1000Ω/0.00mA~30.0A/55mmx32mm Clamp on Earth Resistance Tester,earth ground tester,earth resistance clamp meter,clamp ground tester

1000Ω/30.0A/55mmx32mm Clamp Earth Tester

  • Main Features:: 1.Measure range:0.010Ω~200Ω/c,2,Clamp Size:55mmx32mm
  • Model No.:: MEWOI3000D

Contact Us for QuotationEmail:mewoi@mewoi.comWhatsapp: +8618620373879

INTRODUCTION

Click to download: MEWOI3000D Manual

Click to download: Field Application Guide

MEWOI3000D Clamp Earth Resistance Tester is a major breakthrough in traditional grounding resistance measurement. It is widely used in the grounding resistance measurement of the power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment.

MEWOI3000D Clamp Grounding Resistance Tester, in the measurement of a grounding system with loop, does not require breaking down the grounding down lead, and no need the auxiliary electrode. It is safe, fast and simple in use.

MEWOI3000D clamp grounding resistance meter can measure ground faults which cannot be measured by traditional methods. It can be used in applications where traditional methods cannot be measured, because the MEWOI series clamp grounding resistance meter measures the combined value of grounding body resistance and grounding lead resistance. .

In addition, the D type Clamp Grounding Resistance Tester is also able to measure the leakage current and the neutral current in the grounding system.

Measurement Range & Accuracy

MeasurementRangeResolutionAccuracy
Resistance

0.010Ω-0.099Ω

0.001Ω

±(1%rdg+0.01Ω)

0.10Ω-0.99Ω

0.01Ω

±(1%rdg+0.01Ω)

1.0Ω-49.9Ω

0.1Ω

±(1%rdg+0.1Ω)

50.0Ω-99.5Ω

0.5Ω

±(1.5%rdg+0.5Ω)

100Ω-199Ω

±(2%rdg+1Ω)

200Ω-395Ω±(5%rdg+5Ω)
400-590Ω10Ω±(10%rdg+10Ω)
600Ω-1000Ω20Ω±(20%rdg+20Ω)

Technical Specification

Function

Ground resistance test, Loop resistance test

Resistance Range

0.01-1000Ω

Current Range0.00mA~30.0A

Resistance Resolution

0.001Ω

Current Resolution0.01mA

Alarm symbol indication

Press AL key to turn on / off

Alarm threshold setting range

Resistance:1~199Ω,Current: 1-499mA

Power Supply

6VDC 4 PCS LR6 lkaline batteries

Working Temperature

-10℃-55℃;10%RH-90%RH
LCD Size4 Digits LCD display, Screen: 47mm×28.5mm

Clamp Size

55mm×32mm
Clamp Opening Size32mm
Tester Weight995g
Tester Dimension275mm×85mm×56mm

Protection Level

Double insulation

Structural Feature

Clamp CT

Shift

Automatic shift

External Magnetic Field/Electrical Field<40A/m;<1V/m

Single Measurement Time

1  second

Resistance Measurement Frequency

4>1KHz

Measured Current Frequency

50/60Hz Automatic

Tester Weight

1160g (With batteries)

Clamp Dimension

L×W×T: 285mm×85mm×56mm

Safety Provisions

IEC1010-1, IEC1010-2-032, Pollution level 2, CAT Ⅲ(150V)

Accessories

Meter: 1 piece, Test ring: 1 Piece, Meter Suitcase: 1 Piece

APPLICATION

20101111152555136.jpg

SELECTION GUIDE

Digital Earth Resistance Clamp Meter

Click "blue"marked model No. for detailed Specificaiton

ModelRange
Resolution
clamp sizeRS232Data StorgeOther

MEWOI3000B+

MEWOI3000B+.jpg

0.01Ω-200Ω    0.001Ω65mm×32mmoptional
99sets

MEWOI3100B+

MEWOI3100B+.jpg

ø32mm

MEWOI3000B

MEWOI OEM/ODM  Instruments Manufacturer

55mm×32mm

MEWOI3000

MEWOI OEM/ODM  Instruments Manufacturer

0.01Ω-1000Ω0.001Ω55mm×32mm
99sets

MEWOI3000+

MEWOI3000B+.jpg

0.01Ω-1200Ω 0.001Ω65mm×32mmoptional 99sets

MEWOI3100+

MEWOI3100B+.jpg

ø32mm

MEWOI3000D

MEWOI OEM/ODM  Instruments Manufacturer

0.01Ω-1000Ω

0.00-30.00A

0.001Ω,0.05mA  55mm×32mm
99sets

MEWOI3000D+

MEWOI3000B+.jpg

0.01Ω-1200Ω

0.00-20.00A 

0.001Ω,0.05mA  65mm×32mmoptional 99sets

MEWOI3100D+

MEWOI3100B+.jpg

ø32mm

MEWOI3200

MEWOI3200.80.jpg

0.01Ω-1500Ω

0.00-40.00A 

0.001Ω,0.05mA 

65mm×32m

m

99setsRechargable Batteries

MEWOI3800CA

MEWOI3800CA.80.jpg

0.01Ω-100Ω  0.01Ω60mm*30mm,(Closed)Appoint with RS485 communication interface, provide standard MODBUS-RTU communication protocol×

MEWOI3800DA

MEWOI3800DA.80.jpg

0.01Ω-100Ω  0.01Ω

60mm*30mm

(Closed),

×LCD display,warning function.

MEWOI3800LC

MEWOI3800LC.80.jpg

0.01Ω-200Ω    0.01Ω

Split  Type

56mm×26mm

Wired network: RS232,RS485 standard communication protocol

Wireless network: RS232、RS485、GSM communication protocol

×

MEWOI3800LD

MEWOI3800LD.80.jpg

0.01Ω-200Ω  0.01Ω

Split Type

56mm×26mm

×LCD display,warning function.

MEWOI3900

MEWOI OEM/ODM  Instruments Manufacturer

0.01Ω~2000Ω0.01Ω


2/3-wires measurement

Online

MEWOI3900C

MEWOI OEM/ODM  Instruments Manufacturer

0.01Ω~2000Ω0.01Ω


2/3-wires measurement, Online,GPRS

MEWOI4000

MEWOI4000.80.jpg

0.01Ω~2000Ω;

0~600V

0.01Ω,1V
400sets2/3-wires measurement of earth resistance/voltage

MEWOI4000D

MEWOI OEM/ODM  Instruments Manufacturer

0.01Ω~2000Ω;

0~600V

0.01Ω,1V
400sets2/3-wires measurement of earth resistance/voltage

MEWOI4000C

MEWOI4000C.80.jpg

earth resistance:0.01Ω~30.00KΩ;

soil resistivity:0.01Ωm~9000KΩm;

0~600V

0.01Ω,0.01Ωm,1V
300sets2/3/4-wires measurement of earth resistance,soil resistivity,and earth voltage

MEWOI4200D

MEWOI OEM/ODM  Instruments Manufacturer

earth resistance:0.01Ω~30.00KΩ;

soil resistivity:0.01Ωm~9000KΩm;

0~600V

0.01Ω,0.01Ωm,1V
300sets2/3/4-wires measurement of earth resistance,soil resistivity,and earth voltage

MEWOI4200

MEWOI4200-1_80.jpg

earth resistance:0.01Ω~30.00KΩ;AC Leakage current: 0.00mA~600A;

soil resistivity:0.01Ωm~9000KΩm;Earth Voltage:0.0~100.0V,dual clamp: 0.01Ω-100Ω

0.01Ω,0.01Ωm,0.01A,0.1Vø68mm2000sets2/3/4-wires,selection & dual clamp method to measure the earth resistance,soil resistivity,earth voltage,AC voltage,AC leakage current,warning function.

MEWOI4300D

MEWOI OEM/ODM  Instruments Manufacturer

earth resistance:0.01Ω~30.00KΩ;AC Leakage current: 0.00mA~600A;

soil resistivity:0.01Ωm~9000KΩm;Earth Voltage:0.0~100.0V,dual clamp: 0.01Ω-100Ω

0.01Ω,0.01Ωm,0.01A,0.1Vø68mm2000sets2/3/4-wires,selection & dual clamp method to measure the earth resistance,soil resistivity,earth voltage,AC voltage,AC leakage current,warning function.

MEWOI4250

MEWOI OEM/ODM  Instruments Manufacturer

Ground resistance:0.10Ω ~ 200Ω(4 clamp method)

Ground resistance ( R ):0.10Ω ~ 20KΩ

Soil resistivity ( ρ )0kΩm~9000kΩm

AC current (A~)1mA~500.0A

Ground voltage (V~)0.0V~200.0V

0.01Ω,0.01Ωm,0.01mA,0.1Vø68mm100setsUntie-free tower grounding resistance tester

Technical Specification

Function

Ground resistance test, Loop resistance test

Power Supply

6VDC 4 PCS of AA Alkaline batteries(Rechargable)

Resistance Range

0.01-1500Ω

Resistance Resolution

0.001Ω

Highest Resistance Accuracy

±1%±0.01Ω

Current Range

0.00mA-40.0A

Current Resolution

0.05mA

Highest Current Accuracy

±2.5%±1mA

USB Interface1.5M USB Cable

Data memory

999 Sets

Working Current≤50mA
Start self inspection time≤1s
Clock Functiondisplay hour,minute

Alarm Threshold Setting Range

Resistance: 0-1500Ω,Current: 1-9999A

Alarm Sound and Light

“Beep-beep-beep” alarm tone, Alarm Symbol Flashing, Press AL key to turn on, turn off Alarm or set Alarm Threshold.

Interference Signal Recognition

“Beep-beep-beep” tone, NOISE symbol blinking

Auto Power OffThe instrument does not operate for 5 minutes, then flashes for 30seconds, and then automatically shuts down.

Working Temperature and Humidity

-20℃-55℃;20%RH-90%RH(Please storge and Operate the instrument at its ranges)

LCD Screen

4 Digits LCD display, Screen L×W: 47mm×28.5mm

Clamp Size

65mm×32mm

Clamp Opening Extent

32mm

Tester Weight

1160g (With batteries)

Clamp Dimension

L×W×T: 285mm×85mm×56mm

Protection Level

Dual Insulation

Structural Feature

Clamp CT

Shifting

Automatic shifting

External magnetic field

<40A/m

External electrical field

<1V/m

Single measurement time

0.5 second

Resistance measurement frequency

>1KHz

Measured current frequency

50/60Hz Automatic measurement

Low Battery Indication

Low battery symbol displays when battery is lower then 5.3V

Memory Full Indication

MEM symbol blinks when all 999 sets memory is full

Over Range Indication

Out of range indication “OLΩ”, “L0.01” or “OL A”

Power Consumption

Max 50mA either in booting up or normally working, Continuously working for 30 hours

USB interface

The data stored in the meter are uploaded to the computer through USB interface and data wire, Then generate report files

Safety Provisions

IEC1010-1, IEC1010-2-032, Pollution level 2, CAT Ⅲ(150V)

Accessories

Meter: 1 piece, Test ring: 1 Piece, Meter Suitcase: 1 Piece

Meter: 1 piece, Test ring: 1 Piece, Meter Suitcase: 1 Piece

Telephone
E-mail
After Sales
QQ