MEWOI170-Clamp Φ70mm,AC 0mA~100A Current sensor probe/meter/tester/pinza/alicate amperímetro

Contact Us for Quotation

Email1:mewoi@mewoi.com

Whatsapp: +8618620373879

INTRODUCTION

AC large current, high harmonic current, phase, electric energy, power, power factor and other industrial electricity consumption and electricity metering detection.

Apply for industrial control device, oscilloscope, harmonic analyzer, path analyzer, double clamp earth resistance tester, cable fault tester, power quality analyzer.

Technical Specification

1,Clamp structure, no need to interrupt the power supply and disconnect the circuit in testing, easy to operate, fast, safe and reliable.

2,Input current range: 0mA ~ 1000A, output signal: mA/A;mV/A;1A;5A
3,Output interface: BNC plug/ 4.0mm double banana plug/φ3.5mm Audio plug/Aviation plug(optional), wire length: 2m
4,CT Size: φ70mm.
5,Sensor Dimensions: 223mmX120mmX39mm
6,Weight:680g
7,Safety Level:CAT III 600V
8,Working temperature: -15°C~60°C
9,The input current, output signal and output interface of the sensor can be customized according to customer requirements.

Parameters Optional


Model

Input Current

Output Signal

Frequency

Secondardy Load

Accuracy Class

Series

MEWOI170

0mA~300A

100mA

10Hz~100kHz

0~10A≤500Ω

0~100A≤50Ω

0~1000A≤5Ω

0.5

L0701

0mA~400A

200mA

0.5

L0702

    0mA~600A    600mA
                          0.5            L0703

0mA~1000A

250mA

0.5

L0704

1A~1000A

1mV/A

≥100kΩ

1.0

Y0701

MEWOI170B

500A

1A

40Hz~1kHz

≤2.5VA

0.5

L0720

1000A

1A

≤2.5VA

0.5

L0721

200A

5A

≤5VA

2

L0722

500A

5A

≤5VA

1.0

L0723

1000A

5A

≤5VA

0.5

L0724

SELECTION GUIDE 1

Clamp on Current Sensor Probe For Terminals Such Mulitimeter&Oscilloscope

Click "Blue" marked Model No. to View the Spec

ModelRangeResolution
Clamp SizePower Supply&output
Hall effectCurrent induction output,Direct Coil tap Others
MEWOI107BEMEWOI107BE_副本.8.jpg

0mA~60A

(AC/DC)

1mA  Φ7mm    Power Supply: 9VDC, Output:10mV/A,100mV/A, Accuracy 3%
Suitable for small spaces AC / DC leakage current, low current test.
MEWOI108MEWOI108-1_副本_副本.80.jpg0.0mA~30A (AC)

0.1mA,

Accuracy 0.5%

Φ8 mm

Suitable for small spaces AC leakage current, harmonic, phase, Power test
MEWOI114MEWOI114.80.jpg0.00mA~100A(AC)

0.01mA,

Accuracy 1.0%

Φ14 mm

Suitable for small spaces AC leakage current, harmonic, phase, Power test

MEWOI115

MEWOI OEM/ODM  Instruments Manufacturer

0.00mA~100A0.01mA
17mm×18mm

High accuracy AC leakage current

MEWOI116

MEWOI OEM/ODM  Instruments Manufacturer

0.00mA~20A (AC)0.01mA,1%Φ16mm

High accuracy AC leakage current
MEWOI130MEWOI130.80.jpg0.000mA~60A (AC), 0.001mA,Accuracy: 1%25*30mm

Double shielding, anti-jamming capability,suitable for leakage current,small current test.
MEWOI130EMEWOI130.80.jpg0.00A~10A (DC), 0.01A    25*30mm Power supply: 9VDC, output:0~2.5mV/10mA,Accuracy: 3%,Turns ratio:1:800

Double shielding, anti-jamming capability,suitable for small DC current test.
MEWOI130E2MEWOI130.80.jpg

0.0mA

~100mA

(DC),

0.1mA      25*30mm Power supply: 9VDC, output:0~2.5mV/1mA,Accuracy: 3%,Turns ratio:1:800

Double shielding, anti-jamming capability,suitable for DC leakage current test.
MEWOI130BEMEWOI130BE.0_副本80.jpg0mA~60A (AC/DC)    1mA25*30mmPower supply: 9VDC, output:10mV/A,100mV/A,Accuracy: 2%  
suitable for AC/DC current test
MEWOI135BEMEWOI135BE.80.jpg0.0A~1000A (AC/DC)    0.1A30*35mm     Power supply: 9VDC, output:1mV/1A,Accuracy: 2%  
suitable for AC/DC current test
MEWOI140MEWOI140_副本80.jpg

0.00mA

~300A

(AC)  

Turn Ratio

1:2400

0.01mA,Accuracy: 1%   35*40mm  

Single shielding, suitable for leakage current, small current test
MEWOI140BMEWOI140_副本80.jpg

0.0A~600A (AC)


Turn Ratio

1:4000


0.1A,

Accuracy: 1%

35*40mm

suitable for big current test
MEWOI140CMEWOI140B_副本80.jpg

0.0mA

~100A

(AC)

Turn Ratio

1:2000

0.1mA,

Accuracy: 1%

35*40mm

suitable for current, harmonic, phase, Power test

MEWOI150

MEWOI OEM/ODM  Instruments Manufacturer

0mA ~ 600A AC 1mA,0.5%Φ50mm



MEWOI168MEWOI068-1_副本80.jpg

0.00mA

~1000A

(AC)      

0.01mA,

Accuracy: 1%      

Φ68mm

Double shielding, anti-jamming capability,suitable for leakage current, current test
MEWOI168BMEWOI168.80.jpg0.0A~2000A (AC)

0.1A,

Accuracy: 2%

Φ68mm

suitable for current, harmonic, phase, Power test
MEWOI168CMEWOI168.80.jpg0.00A~1000A (AC)

1mA,

Accuracy: 2%

Φ68mm

suitable for current, harmonic, phase, Power test
MEWOI168BEMEWOI168BE-80.jpg

0.0A~2000A (DC),

0.0A~1000A(AC)

0.1mAΦ68mm

Power supply: 9VDC,

output:1mV/1A,

Accuracy: 2%


suitable for AC/DC big current test

MEWOI170

MEWOI OEM/ODM  Instruments Manufacturer

0mA ~ 1000A1mAΦ70mmoutput signal: mA/A;mV/A;1A;5A


SELECTION GUIDE 2

Flexible Coil Current Sensor Probe For Terminals Such as Mulitimeter&Oscilloscope

Click "Blue" marked Model No. to View the Spec

Model
Flexible CTRangeResolutionCoil lengthDiameterApplication
MEWOI200G1638949745411743.jpgΦ100 mm

AC

10mA~10000A~more

10mA315mm (Can be customized)φ7.5mm(suitable for narrow and cable-intensive places)



Measure AC big current, high harmonic currents, complex Waveforms current,   inrush transient current.


Suitable for measuring the size of a large or irregularly shaped conductor current

MEWOI300G1638949813964859.jpgΦ200 mm

AC

10mA~10000A~more

10mA630mm (Can be customized)φ7.5mm(suitable for narrow and cable-intensive places)
MEWOI400G1638949844933195.jpgΦ300 mm

AC

10mA~10000A~more

10mA1000mm (Can be customized)φ7.5mm(suitable for narrow and cable-intensive places)

Technical Specifications

Function

Measurement of AC current, leakage current, high order harmonic

current, phase, power energy, power, power factor

Test mode

Clamp CT

Clamp Size

35mm×40mm

Range

0.0~600A  AC

Resolution

0.1A AC

Accuracy

±1.0%FS(50Hz/60Hz; 23°C±2°C, below 70%RH, keep the wire be in the center of clamp)

Coils Turn

1:4000

Phase Error

≤3°(50Hz/60Hz; 23°C±2°C)

Reference Load

RL:0~300mA≤500Ω; 0~3A≤50Ω; 0~30A≤5Ω; 0~300A≤0.5Ω

Output Mode

Current induction output

Output Interface

φ3.5mm audio plug or Choose two root welding thread or standard multi-meter pen plugs

Output Wire Length

2m

Electric Field Interference

About 10mA when the external electric field 100A, 10mm nearby

Measured Wire Position

Approximately in the geometric center of the clamp

Current Frequency

45H-60Hz(when measuring big current)

Frequency Characteristics

10Hz~100kHz

Line Voltage

Below AC 600V

Dimension

120mm×70mm×33mm

Weight

190g

Working Environment

-20°C-50°C; below 80%rh

Storage Environment

-10°C-60°C; below 70%rh

Insulation Strength

AC3700V/rms (between core and shell)

Safety Rules

IEC1010-1, IEC1010-2-032, Pollution degree 2, CAT III (600V)

1*clamp meter,User Manual

Telephone
E-mail
After Sales
QQ