INTRODUCTION
Click to download: MEWOI3800P Manual
| MEWOI3800P built-in grounding resistance tester is designed specifically for online monitoring connection status of ground lead , loop grounding resistance, metal loop resistance . Online testing, non-contact measurement, ground lead through the clamp,without self-test, real-time detection. Provide RS232, RS485 or MODBUS-RTU communication protocol, the sensor and circuit board can be built in o the chassis of other equipment, user-friendly secondary development and integration. MEWOI3800P built-in grounding resistance online detector can be used for power transmission tower grounding; underground mine equipment grounding; meteorological lightning protection grounding; petrochemical grounding; communication grounding; transformer/substation grounding; railway facility grounding; construction warehouse grounding; electrical equipment grounding,etc. Can also be used for ground wire, metal cable anti-theft monitoring. MEWOI3800P built-in grounding resistance tester can be installed on a single use, can also be formed in o a wired network system or wireless network system. | 
SPECIFICATION
| Functions | Circuit grounding resistance monitoring, metal loop resistance on-line monitoring, ground condition monitoring; ground wire, metal cable anti-theft monitoring. | 
| Range | 0.01Ω~200Ω | 
| Resolution | 0.01Ω | 
| Output range | 0.00Ω~200Ω | 
| Accuracy | ±2%rdg±3dgt(20℃±5℃,<70%RH) | 
| Power Supply | 6VDC~9VDC,50mA Max. | 
| Weight | 680g | 
| Host Size | 110mm×80mm×55mm | 
| PCB Size | 166mm×56mm×20mm | 
| Ground perforation size | 66mm×36mm,Closed Type | 
| Extend Wire | 1pc,1Meter(5Cores Wire) | 
| Single Test Time | About 0.5Second | 
| PCB Interface | J1,Signal output, power input interface J2,The connection interface between the Host and PCB | 
| J1 Identification | P+:Power Output+ P-:Power Input- GND:Signal,Connect with Power Input(P-) R+:Singal Output+ R-:Signal Input- | 
| J2 Identification | I +, I-current coil interface U +, U-voltage coil interface GND: Common ground | 
| Connection Line Identificatin | Red / brown --- Power input positive; Black - Power input ground; Blue --- RS485 signal is positive; Gray --- RS485 signal is negative; White --- shield to; (Power input ground and shield can be short-circuit connection) | 
| Communication Method | RS232, RS485 or MODBUS-RTU communication protocol | 
| Overflow indication | When the display value is greater than 200Ω, the communication sends an "OLΩ" command | 
| Working Temperature and Humidity | -20℃~50℃; below 90%rh | 
| Storage Temperature and Humidity | -20℃~60℃; below 70%rh | 
| Temperature and humidity error | Less than 5% | 
| External magnetic field | <40A/m | 
| External electric field | <1V/m | 
| Install | The ground wire passes through the center hole of the sensor | 
| Installation Requirements | Circuit boards need to be placed in other protective box, to avoid rain, flooding installation | 
| Power consumption | 50mA Max. | 
| Power supply | External power supply | 
| Ground interference current | Should be avoided | 
| Shift | Automatic shift | 
| Accessories | Sensor: 1 pc; PCB module: 1 pcs; Connection cable: 1 piece | 
SPECIFICATION
| Functions | Circuit grounding resistance monitoring, metal loop resistance on-line monitoring, ground condition monitoring; ground wire, metal cable anti-theft monitoring. | 
| Range | 0.01Ω~200Ω | 
| Resolution | 0.01Ω | 
| Output range | 0.00Ω~200Ω | 
| Accuracy | ±2%rdg±3dgt(20℃±5℃,<70%RH) | 
| Power Supply | 6VDC~9VDC,50mA Max. | 
| Weight | 680g | 
| Host Size | 110mm×80mm×55mm | 
| PCB Size | 166mm×56mm×20mm | 
| Ground perforation size | 66mm×36mm,Closed Type | 
| Extend Wire | 1pc,1Meter(5Cores Wire) | 
| Single Test Time | About 0.5Second | 
| PCB Interface | J1,Signal output, power input interface J2,The connection interface between the Host and PCB | 
| J1 Identification | P+:Power Output+ P-:Power Input- GND:Signal,Connect with Power Input(P-) R+:Singal Output+ R-:Signal Input- | 
| J2 Identification | I +, I-current coil interface U +, U-voltage coil interface GND: Common ground | 
| Connection Line Identificatin | Red / brown --- Power input positive; Black - Power input ground; Blue --- RS485 signal is positive; Gray --- RS485 signal is negative; White --- shield to; (Power input ground and shield can be short-circuit connection) | 
| Communication Method | RS232, RS485 or MODBUS-RTU communication protocol | 
| Overflow indication | When the display value is greater than 200Ω, the communication sends an "OLΩ" command | 
| Working Temperature and Humidity | -20℃~50℃; below 90%rh | 
| Storage Temperature and Humidity | -20℃~60℃; below 70%rh | 
| Temperature and humidity error | Less than 5% | 
| External magnetic field | <40A/m | 
| External electric field | <1V/m | 
| Install | The ground wire passes through the center hole of the sensor | 
| Installation Requirements | Circuit boards need to be placed in other protective box, to avoid rain, flooding installation | 
| Power consumption | 50mA Max. | 
| Power supply | External power supply | 
| Ground interference current | Should be avoided | 
| Shift | Automatic shift | 
| Accessories | Sensor: 1 pc; PCB module: 1 pcs; Connection cable: 1 piece | 
Sensor: 1 pc; PCB module: 1 pcs; Connection cable: 1 piece