MEWOI1100C+-AC 0.0mA-1200A φ50mm 60KV Wireless High Voltage Clamp Meter

  • Name:
    MEWOI1100C+-AC 0.0mA-1200A φ50mm 60KV Wireless High Voltage Clamp Meter
  • Model No.:
    MEWOI1100C+
  • Main Features:
    1,Clamp size: 50mm,2,AC Current:0.0mA~1200A 3,Data Storage: 200sets,4, Voltage range: 60KV
OEM/ODM Testing Instruments Manufacturer
share:

INTRODUCTION

Click to download: MEWOI1100C+ User Manual

Click to download:  MEWOI1100C+ Color Page

MEWOI1100C+H/L Voltage Clamp Meter has broken through the traditional structure, which is specially well-designed for measuring high voltage current, adopting the latest CT technology and integrated mask digital technology, formed by composition of a special use clamp meter with a high-voltage insulation rod, it is equipped with wireless receivers, which can receive measured data within 30 meters line. If not using an insulation rod, it can be also used as a high precision low-voltage clamp meter, or an alternating current meter, which can accurately measure 0.1mA of current or leakage current.

MEWOI1100C+H/L Voltage Clamp Meter has an innovative integrated design between transducer clamp and transducer domain, ensuring the high-precision, high-reliability, and high-stability on constant test perennially.

MEWOI1100C+H/L Voltage Clamp Meter is connected with insulation rod, which can be used for measuring high voltage current that is below 60KV, on-line current measurement, also having peak maintenance, data preservation, data storage, wireless transmission and other functions, and its special clamp meter can make it easier for clamping or evacuating the tested wire through pressing or pulling back the insulation rod, time-saving and fast, widely used in transformer substation, power plant, industrial and mining enterprises as well as the inspection station and electrician maintenance departments for electrical current detection and field electrical operations. The insulation rod is light and convenient, with the advantages of anti-moisture, high temperature resistance, anti-impact, bending resistance, high insulation, flexibility and other characteristics.

TECHNICAL SPECIFICATION

Function

 High voltage AC current measurement, low voltage AC current, current leakage measurement, online AC current measurement 

Power Supply

Tester(DC6V alkaline dry battery(1.5V AAA×4)), *Receiver Battery (DC7.5V Alkaline Dry Battery)*4

Test Mode

Clamp CT, integral approach

 Display Mode

4 bit LCD display, with backlight function

Transmission ModeWireless transmission, the maximum distance of straight line transmission is about 30m

LCD Dimension

48mm×31mm

Meter Dimension

W/H/T: 87mm×262mm×37mm

Clamp Dimension

Ф50mm

Sampling Rate

2 times/second

Measurement Scope

0.0mA~1200A (50/60Hz automatic)

Resolution

0.1mA

Shift

0.0mA~1200A automatic shift

Accuracy

(23℃±5℃, below 70%RH)

(23℃±5℃, below 70%RH),0.0mA~299mA:      ±1%±3dgt ,0.30A~9.99A:      ±1.5%±5dgt ,10.0A~199.9A:     ±2%±5dgt

200A~399A:        ±2.5%±5dgt   ,400A~600A:        ±3%±5dgt   ,601A~1200A:       ±4%±5dgt 

Line Voltage

Below 60KV line test (with 5 insulation rods operation,Bare wire35KV)

Data Memory

200 sets, memory process is shown by MEM , full storage is shown by blinking  FULL

PEAK value maintaining

Automatically maintain the high test value, in usual testing mode, press key HOLD till the lighting of PEAK, that is, start PEAK to maintain this function. 

Data Hold

In usual testing mode, press HOLD key to keep data, shown by “HOLD”

Data Access

 “MR” indication, can access to all data

Overflow Display

Over-range overflow function: shown in “OL  A”

Automatic Shutdown

15 minutes after boot

Battery Voltage

When battery voltage is lower than 4.8V, battery voltage is shown in low symbol to remind battery replacement

Meter Weight

Detector: 335g (with battery), the total mass of meter: 2.5kg (including insulation rod and battery)

Working Temperature and Humidity

-25℃~40℃; below 80%Rh

Storage Temperature and Humidity

-10℃~60℃; below 70%Rh

Insulation Rod Dimension

φ32mm, 1m/piece (5pieces)

Insulation Strength

AC 100kV/rms (between the 5th insulation rod and high voltage current clamp core)

Structure

Anti-drip type Ⅱ

Safety Provisions

IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard)

Accessories

Clamp Meter : 1 piece; meter box: 1 piece; insulation rod (1m): 5 pieces; battery (alkaline battery AAA): 8 pieces

MEWOI H/L Voltage Current Clamp Meter Selection Guide(Click the "Blue"Marked model No.to view the Spec)

Model No.Product NameAC RangeDefinitionClamp SizeData StorgeCircuit VoltageOther

MEWOI1000

MEWOI1000.Fluke.80.jpg

H/L Voltage Clamp Meter

AC  0.0mA~

1200A

0.0mA Automatic 

Shift 

φ50mm99setsbelow 60KV(operated with insulation rod,Bare wire35KV)

MEWOI1000C

MEWOI1000C.Extech.80.jpg

Wireless H/L Voltage Clamp Meterwireless(Distance:30M)

MEWOI1000T

MEWOI1000T.Extech.80.jpg

Portable H/L Voltage Clamp Meter

MEWOI1100

MEWOI1100.HIOKI.80.jpg

H/L Voltage Clamp Current MeterAC  0.00mA~600A0.01mAφ33mm99setsbelow 60KV(operated with insulation rod,Bare wire35KV)

MEWOI1100+

MEWOI1100+.01_80.jpg

H/L Voltage Clamp Current MeterAC  0.0mA~1200A0.1mAφ50mm99sets

MEWOI1100C

MEWOI1100C.Extech.80.jpg

Wireless H/L Voltage Clamp Current MeterAC  0.0mA~1200A0.1mAφ33mm99setsbelow 60KV(operated with insulation rod,Bare wire35KV)wireless(Distance:30M)

MEWOI1100C+MEWOI1100C+.01_80.jpg


Wireless H/L Voltage Clamp Current MeterAC  0.0mA~1200A0.1mAφ50mm200sets
MEWOI1100T

MEWOI1100T.HIOKI.80.jpg

Portable H/L Voltage Clamp Current MeterAC  0.00mA~600A0.1mAφ33mm99setsbelow 10KV(operated with insulation rod,Bare wire 1KV)
MEWOI1200

MEWOI1200.Extech.80.jpg

H/L Voltage Clamp Current MeterAC  0.00mA~1000A(0.00mA~1600A Optional)0.01mAφ68mm99setsbelow 60KV(operated with insulation rod,Bare wire35KV)

MEWOI1200C

MEWOI1200C.80.jpg

Wireless H/L Voltage Clamp Current Meter99setswireless(Distance:30M)

MEWOI400

MEWOI400.400B.80.jpg

Wireless H/L Voltage Hook Type Current MeterAC 0~6000A10mA;0.1HzФ168mm Conductor or cable, or 168mm×245mm bus bar9999sets
below 110KV(operated with insulation rod,Bare wire35KV)wireless(Distance:150M)

MEWOI400B

MEWOI400.400B.80.jpg

Wireless H/L Voltage Hook Type Current MeterAC 0~20.0kA10mA;0.1HzФ168mm Conductor or cable, or 168mm×245mm bus bar9999setsbelow 110KV(operated with insulation rod,Bare wire35KV)wireless(Distance:150M)

TECHNICAL SPECIFICATION

Function

 High voltage AC current measurement, low voltage AC current, current leakage measurement, online AC current measurement 

Power Supply

Tester(DC6V alkaline dry battery(1.5V AAA×4)), *Receiver Battery (DC7.5V Alkaline Dry Battery)*4

Test Mode

Clamp CT, integral approach

 Display Mode

4 bit LCD display, with backlight function

Transmission ModeWireless transmission, the maximum distance of straight line transmission is about 30m

LCD Dimension

48mm×31mm

Meter Dimension

W/H/T: 87mm×262mm×37mm

Clamp Dimension

Ф50mm

Sampling Rate

2 times/second

Measurement Scope

0.0mA~1200A (50/60Hz automatic)

Resolution

0.1mA

Shift

0.0mA~1200A automatic shift

Accuracy

(23℃±5℃, below 70%RH)

(23℃±5℃, below 70%RH),0.0mA~299mA:      ±1%±3dgt ,0.30A~9.99A:      ±1.5%±5dgt ,10.0A~199.9A:     ±2%±5dgt

200A~399A:        ±2.5%±5dgt   ,400A~600A:        ±3%±5dgt   ,601A~1200A:       ±4%±5dgt 

Line Voltage

Below 60KV line test (with 5 insulation rods operation,Bare wire35KV)

Data Memory

200 sets, memory process is shown by MEM , full storage is shown by blinking  FULL

PEAK value maintaining

Automatically maintain the high test value, in usual testing mode, press key HOLD till the lighting of PEAK, that is, start PEAK to maintain this function. 

Data Hold

In usual testing mode, press HOLD key to keep data, shown by “HOLD”

Data Access

 “MR” indication, can access to all data

Overflow Display

Over-range overflow function: shown in “OL  A”

Automatic Shutdown

15 minutes after boot

Battery Voltage

When battery voltage is lower than 4.8V, battery voltage is shown in low symbol to remind battery replacement

Meter Weight

Detector: 335g (with battery), the total mass of meter: 2.5kg (including insulation rod and battery)

Working Temperature and Humidity

-25℃~40℃; below 80%Rh

Storage Temperature and Humidity

-10℃~60℃; below 70%Rh

Insulation Rod Dimension

φ32mm, 1m/piece (5pieces)

Insulation Strength

AC 100kV/rms (between the 5th insulation rod and high voltage current clamp core)

Structure

Anti-drip type Ⅱ

Safety Provisions

IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard)

Accessories

Clamp Meter : 1 piece; meter box: 1 piece; insulation rod (1m): 5 pieces; battery (alkaline battery AAA): 8 pieces

Clamp Meter : 1 piece; meter box: 1 piece; insulation rod (1m): 5 pieces; battery (alkaline battery AAA): 8 pieces

You may like