| Function | High voltage AC current measurement, low voltage AC current, current leakage measurement, online AC current measurement | 
| Power Supply | DC6V alkaline dry battery(1.5V AAA×4) | 
| Test Mode | Clamp CT, integral approach | 
| Transmission Mode | Wireless transmission, the maximum distance of straight line transmission is about 30m | 
| Display Mode | 4 bit LCD display, with backlight function | 
| LCD Dimension | 47mm×28.5mm | 
| Meter Dimension | Width, height, thickness: 76mm×255mm×31mm | 
| Clamp Dimension | Ф48mm | 
| Sampling Rate | 2 times/second | 
| Measurement Scope | 0.0mA~1200A (50/60Hz automatic) | 
| Resolution | 0.1mA | 
| Shift | 0.0mA~1200A automatic shift | 
| Accuracy (23℃±5℃, below 70%RH) | 0.0mA~299mA:      ±1%±3dgt | 
| 0.30A~9.99A:      ±1.5%±5dgt | 
| 10.0A~199.9A:     ±2%±5dgt | 
| 200A~399A:        ±2.5%±5dgt   | 
| 400A~600A:        ±3%±5dgt   | 
| 601A~1200A:       ±4%±5dgt   | 
| Line Voltage | Below 110KV line test (with 5 insulation rods operation) | 
| Data Memory | 99 sets, memory process is shown by  MEM , full storage is shown by blinking  “FULL” | 
| PEAK value maintaining | Automatically maintain the high test value, in usual testing mode, press key HOLD till the lighting of PEAK, that is, start PEAK to maintain this function.   | 
| Data Hold | In usual testing mode, press HOLD key to keep data, shown by “HOLD” | 
| Data Access | “MR” indication, can access to all data | 
| Overflow Display | Over-range overflow function: shown in “OL  A” | 
| No Signal Indication | “no- -” is shown when receiver does not receive the dynamic display of signal transmission | 
| Automatic Shutdown | 15 minutes after boot | 
| Battery Voltage | When battery voltage is lower than 4.8V, battery voltage is shown in low symbol to remind battery replacement | 
| Meter mass | Detector: 575g (with battery), Total Weight : 7kg (including 5pcs insulation rods, battery,Bag, and Protection box) | 
| Working Temperature and Humidity | -25℃~40℃; below 80%Rh | 
| Storage Temperature and Humidity | -10℃~60℃; below 70%Rh | 
| Insulation Rod Dimension | φ32mm, 1m/piece (5pieces) | 
| Insulation Strength | AC 100kV/rms (between the 5th insulation rod and high voltage current clamp core) | 
| Structure | Anti-drip type Ⅱ | 
| Safety Provisions | IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard) | 
| Accessories | Clamp: 1 piece; receiver: 1 piece; meter box: 1 piece; insulation rod (1m): 5 pieces; battery (alkaline battery AAA): 8 pieces |