MEWOI248B 0.0A~4000A 148mm×108mm Super-large Caliber Clamp AC Current Sensor

Electricity Testing Instruments manufacturer, Support OEM/ODM, your testing specialist

Contact Us for QuotationEmail:mewoi@mewoi.comWhatsapp: +8618620373879

Ⅰ.INTRODUCTION

Click to download: MEWOI248,248B Super-large Caliber Clamp AC Current Sensor User Manual

MEWOI248,MEWOI248B Super-large Caliber Clamp Current Sensor is well designed and manufactured for measurement of AC current, higher harmonic current, phase, electric energy, power and power factor, by adopting the latest CT technology. Its large caliber 148mm×108mm can clamp electric cable of Φ108mm, or 160mm×4mm flat cable and steel earth wires. It is portable, clamp designed, no need to disconnect the circuit, non-contact measurement, which means safer and faster. It can be connected with phase detection analyzer, industrial control equipment, data recorder, oscilloscope, electric power quality analyzer, high precision multi-meter, widely applied in those fields as electricity, communications, meteorology, railroad, oilfield, construction, measurement, scientific & research teaching institutes, industrial and mining establishments.

The clamp is made of special alloy, adopt the latest CT and magnetic shielding techniques, can almost shield the influence from external magnetic field, to ensure the high precision, high stability and high reliability of perennial uninterrupted measurement

SELECTION GUIDE

ModelRangeResolutionCoils Turn
ShieldNotes
MEWOI2480.mA~3000A0.1mA1:3000YesStrong anti-interference ability and more suitable for leakage current test
MEWOI248B0.0A~4000A0.1A1:3000NoSuitable for large current testing

TECHNICAL SPECIFICATION

FunctionMeasurement of AC current, higher harmonic current, phase, electric energy, power and power factor
Test modeClamp CT
Clamp Size148mm×108mm
RangeAC 0.0A-3500A
ResolutionAC 0.1A
Accuracy±2.0%FS (50Hz/60Hz; 23℃±2℃, below 70%RH, keep the measured wire be in the center of the clamp)
Coils Turn3000: 1
Phase Error≤3°(50Hz/60Hz; 23℃±2℃)
Reference LoadRL: 0-300mA≤3kΩ; 0-30A≤30Ω; 0-4000A≤0.3Ω
Output ModeCurrent induction output
Output Interface2 bare wires or standard multi-meter pen plug
Output Wire Length2m
Electric Field InterferenceAbout 5mA when the external electric field 100A, 10mm nearby
Measured Wire PositionApproximately in the geometric center of the clamp
Current Frequency45H-60Hz(when measuring big current)
Frequency Feature10Hz~100kHz
Voltage of circuitBelow AC 600V
Dimension350mm×180mm×55mm
Weight1.5Kg
Working Environment-20℃ ~ 50℃; below 80%rh
Storage Environment-10℃ ~60℃; below 70%rh
Insulation StrengthAC 3700V/rms.(between coil and shell)
Safety RulesIEC1010-1, IEC1010-2-032, 2 class of pollution, CAT Ⅲ(600V)
Telephone
E-mail
After Sales
QQ