MEWOI135BE mini Clamp on AC/DC Current Sensor probe/meter

  • Características:
    1,AC/DC leakage and current detection 2, Range: 0.0A~600A 3,clamp size:30mm×35mm
  • Modelo:
    MEWOI135BE
  • Nombre:
    MEWOI135BE mini Clamp on AC/DC Current Sensor probe/meter
Electricity Testing Instruments manufacturer, Support OEM/ODM, your testing specialist
share:

MEWOI135BE mini Clamp on AC/DC Current Sensor probe/meter

Ⅰ.Introduction

MEWOI135BE Clamp AC/DC Current Sensor is specially designed to test current and leakage of circuit below AC/DC600, with small size, high accuracy, and good stability. It is widely applied in AC current leakage, current, power and energy measurement with high precision and small phase error of electricity, communications, meteorology, railway, oilfield, construction, measurement, scientific and research teaching unit, industrial and mining enterprises, which can be connected to a variety of high precision digital multi-meter and data recorder.

Ⅱ.Application

MEWOI145BE application.png


Ⅲ.Selection Guide

ModelRangeResolution
Clamp SizePower Supply&output
Hall effectCurrent induction output,Direct Coil tap Others
MEWOI107BEMEWOI107BE_副本.8.jpg

0mA~60A

 (AC/DC)

1mA  Φ7mm    Power Supply: 9VDC, Output:10mV/A,100mV/A, Accuracy 3%
Suitable for small spaces AC / DC leakage current, low current test.
MEWOI108MEWOI108-1_副本_副本.80.jpg0.0mA~30A (AC)

0.1mA,

Accuracy 0.5% 

Φ8 mm 

Suitable for small spaces AC leakage current, harmonic, phase, Power test
MEWOI130MEWOI130.80.jpg0.000mA~60A (AC), 0.001mA,Accuracy: 1%25*30mm 

Double shielding, anti-jamming capability,suitable for leakage current,small current test.
MEWOI130EMEWOI130.80.jpg0.00A~10A (DC),  0.01A    25*30mm Power supply: 9VDC, output:0~2.5mV/10mA,Accuracy: 3%,Turns ratio:1:800 

Double shielding, anti-jamming capability,suitable for small DC current test.
MEWOI130E2MEWOI130.80.jpg

0.0mA

~100mA (DC), 

0.1mA      25*30mm Power supply: 9VDC, output:0~2.5mV/1mA,Accuracy: 3%,Turns ratio:1:800 

Double shielding, anti-jamming capability,suitable for DC leakage current test.
MEWOI135BEMEWOI135BE.80.jpg0.0A~1000A (AC/DC)    0.1A30*35mm     Power supply: 9VDC, output:1mV/1A,Accuracy: 2%   
suitable for AC/DC current test
MEWOI140MEWOI140_副本80.jpg

0.00mA

~300A

 (AC)  

Turn Ratio

1:2400

0.01mA,Accuracy: 1%   35*40mm  

Single shielding, suitable for leakage current, small current test
MEWOI140BMEWOI140_副本80.jpg

0.0A~600A (AC)


Turn Ratio

1:4000


0.1A,

Accuracy: 1% 

35*40mm 

suitable for big current test
MEWOI140CMEWOI140B_副本80.jpg

0.00mA

~300A

 (AC)

Turn Ratio

1:2000

0.01mA,

Accuracy: 1%

35*40mm

suitable for current, harmonic, phase, Power test
MEWOI168ETCR068-1_副本80.jpg

0.00mA

~1000A 

(AC)       

0.01mA,

Accuracy: 1%       

Φ68mm 

Double shielding, anti-jamming capability,suitable for leakage current, current test
MEWOI168BMEWOI168.80.jpg0.0A~2000A (AC)

0.1A,

Accuracy: 2%

Φ68mm 

suitable for current, harmonic, phase, Power test
MEWOI168CMEWOI168.80.jpg0.00A~1000A (AC)

1mA,

Accuracy: 2% 

Φ68mm

suitable for current, harmonic, phase, Power test
MEWOI168BEMEWOI168BE-80.jpg

0.0A~2000A (DC),

0.0A~1000A(AC)

0.1mAΦ68mm

Power supply: 9VDC,

output:1mV/1A, 

Accuracy: 2%


suitable for AC/DC big current test

Technical Specification

Function

AC/DC current detection

Power Supply

Battery, 6LR61 9VDC (can connect external power supply)

Test model

Clamp CT, Non contact measurement, non-exposure of meter of the jaw

Dimension

185mm×70mm×38mm

Clamp Size

30mm×35mm

AC Frequency

45~400Hz

Range

AC/DC 0.0A~600A

Resolution

0.1A

Accuracy

1%(23±3,below 70%RH)

Output

1mV/A

Frequency Response

10KHz(-3dB)

Zero-Adjustment

Yes

Lead length

2m

Wire Position

Detected wire should be put on the centre of the jaw

Circuit Voltage

Lower than AC600V

Power on/off

Push ON/OFF key

Battery Voltage

Indicating the battery voltage is lower then 7.2V.Then the battery have to be changed

Weight

180g(including the battery)

Consumption

10mW

Auto Power-off

5 Minutes after power on, it will power off automatically to lower the power consumption

Working environment

-20~50;below 80%rh

Storage environment

-10~60;below 70%rh

Max error refer to environment

-10~0 or 40~50,Error will increase max to 1%rdg

Insulation strength

AC2kV/rms (between core and shell)

Safety rules

IEC1010-1, IEC1010-2-032, Pollution degree 2,CAT (600V)

Accessories

Sensor:1PC; Battery (6F22 9V): 1PC

Sensor:1PC; Battery (6F22 9V): 1PC